Automotive Cables to ISO, SAEJ, JASO D Automotive Cables. APPLICATIONS OVERVIEW. Standard wall automotive cables are ideal for use in. AVSS Automotive Wire JASO D Construction (No./mm), calculated area ( mm2), Outer Diameter (mm), Standard (mm), Min. (mm), Standard (mm), Max. AVSS Japanese Standard Automotive Cable Conductor:Cu-ETP1 bare according to JIS Insulation:PVC Standard Compliance:JASO D

Author: Kajijora Tem
Country: Sudan
Language: English (Spanish)
Genre: Video
Published (Last): 16 February 2008
Pages: 66
PDF File Size: 10.21 Mb
ePub File Size: 20.77 Mb
ISBN: 237-6-35370-823-7
Downloads: 59289
Price: Free* [*Free Regsitration Required]
Uploader: Moogusida

Conductor Number of Calculated Nominal Approx. The symbol “f” in the “Nominal size” column means flexible conductor.

Compressed conductor extremely thin wall halogen-free insulated low-voltage cables for automobiles CAVUS: In addition, the necessity and method of voltage indication must be discussed to establish its future direction. Conductor Calculated Nominal Number of Approx. The impact test shall be conducted staandard accordance with the method specified in 5. The types and symbols are summarized and described in Table 1.

Wire Cable, Jaso D611 Standards Avss Type Automotive Wire PVC Insulation, Wire Harness

Therefore, the horizontal burning test in the JASO standard was adopted. Construction and material 5. Packaging Sstandard shall be packaged either on a reel or in bundle, and such that they are not easily damaged during transportation.

Maximum shrinkage length on both ends shall be 2 mm after being heated as specified. Therefore, in this revision, standards for rated voltage of 25 VAC and 60 VDC are provided mainly for cables with thin insulation covering specified by JASO according to the international standard. To check the rated voltage, refer to the “name or symbol and nominal size” indicated on the cable, cable frame, or bundle. Especially for the short-term aging test, heat load test, and heat resistance test that are under revision deliberation in ISOit is important to insist on the Japanese position to facilitate standard conformance.

  LA BAJA EDAD MEDIA JULIO VALDEON PDF

Conductor Calculated Nominal Approx. The construction shall conform to the applicable standard in Tables 11 to 25 when the test is conducted according to Item 6. Inthe standard was revised to include these cables.

AVSS JASO D | Balaji Wires

However, the conductor material for nominal size 0. At the time of establishment, thin wall low-voltage cables generally called AVS that have thinner insulation covering and thin wires with a conductor sectional area of 5 mm2 or less were widely used to reduce the weight and size of wire harnesses d6611 automobiles.

Marking The following items shall be marked on the packaged products using indelible ink.

Thin wall low-voltage cables “type 1” for automobiles 0. The meanings of the heat resistant are as follows. This test is applicable to the nominal sizes of 5 or less.

China UL, Jaso D Standards AVS Type Automotive Wire Photos & Pictures –

The insulation shall not be fractured when d11 specified voltage is applied. The meanings of the symbols for cable types are as follows. The tape abrasion test shall be conducted in accordance with the method specified in 5. For this reason, the current details are applied unchanged. Scope This standard specifies low-voltage cables hereinafter referred to as “cables” used as unscreened single-core low-voltage cables for automobiles, excluding AV low-voltage cables for automobiles specified in JIS C Standad revision increased the number of types significantly, but the standard now covers all types in consideration of the current production and distribution status.

These types and symbols must be organized and integrated in accordance with ISO standards in order to increase international competitiveness in the future.

Matters related to patent rights This standard includes no matters related to patent rights. Halogen-free insulated low-voltage cables for 6d11 AVS: However, gasoline, diesel fuel, and engine oil must be always tested. Normative reference The following standards, when referred to in this standard, constitute a part of the specifications of this standard.

  ELECTROMYOGRAPHY EXPERIMENTALISTS PDF

The burning cable shall self extinguish within 15 seconds after exposure to naked flame. Minimum number of abrasion cycles shall be as specified in Table This is caused by the difference in the concept of temperature resistance as shown in Note 2 of Table 1, and it was determined to describe both values separately depending on the cable types.

In addition, the cables conforming to ISO in this revision are as follows: However, since cables are actually handled with these multiple symbols, serial indication of multiple symbols was adopted to avoid confusion.

UL, Jaso D611 Standards AVS Type Automotive Wire

Extremely thin wall type cross-linked polyethylene insulated heat resistant low-voltage cables for automobiles Note 2: The conductor shall not be exposed after the test. Scope All previous automotive low-voltage cable standards JIS C established inwhich was the first standard for this subject in Japan, JASO D established in in which the insulation covering was made thinner, and D established in were created without concern about the rated voltage of the cables because the cables were applied to automotive electric systems with the international standard of 12 V and 24 V, and have been used continuously.

The tests requiring different performance depending on the nominal size are described in Table 8 to